In other words low ceiling height under approx.
Infrared tube heaters vs forced air.
I am waffling between going with an overhead forced air furnace or using radiant tubes hung from the ceiling.
Radiant heaters forced air garage heaters use a fan to draw in cold air heat it and then blow it throughout the space making them an efficient way to warm up bigger spaces.
I currently have radiant tube heaters in my shop and i don t think i will ever go back to forced air again.
With infrafed heaters you don t have to wait to warm up with you step in from the cold like with.
I know there are tons of posts on garage heaters in general i am specifically looking for opinions on radiant tubes vs forced air.
My first install on any garage is a heater.
There are lots of advantages for using radiant tube heating.
I typically keep the garage about 5 degrees daily during the winter and crank it up when i plan to.
Infrared tube heaters consist of two main sections the burner box and typically 4 round metal tubes that are anywhere from roughly 20 80 long with polished reflectors.
Radiant heaters are generally more efficient than forced air.
With the radiant tubes you only have a heat difference of 2 3.
If you climb up on a ladder in a shop with forced air you will find it is a lot hotter up by the ceiling than down on the floor sometimes 30 40 degrees.
I have purchased a property that has a 1 000 square foot shop 12 foot ceiling.
They re both effective ways to heat small spaces but operate in radically different ways.
It has natural gas to the building but no furnace.
Convection heaters warm the air.
Radiant heaters warm your body which leads many consumers to ask what s more effective convection hea.
Forced air or radiant tube.
Forced air heaters vs.
14 is ideal for a forced air unit while higher ceiling heights are practical for infrared radiant tube heaters.
In my last 2 garages i have had forced air furnaces they have done the job but of course the floor is still freezing.
The two most common space heaters on the market are convection heaters and radiant heaters.
The service bays in the rear had been using forced air heaters to heat the space for over 20 years.
The infrared heater safety council says the average fuel savings is about 30 although some manufacturers claim even larger savings.
Next take a look at your room size and insulation.
This is a vented heater and is better suited to woodworking shops and for spaces 600 to 1200 square feet.
The other option is an infrared radiant tube heater.
Infrared heaters work instantly.
The burner box delivers hot gas to the tubes making the tubes extremely hot and the heat radiates from the tubes to the space.